Software

ASTM C114 PDF

C – 00 Standard Test Methods for Chemical Analysis of Hydraulic Cement, chemical analysis, compositional analysis, hydraulic cements. ASTM Standards: 2. C 25 Test Methods for Chemical Analysis of Limestone,. Quicklime, and Hydrated Lime. D Specification for Reagent Water. ASTM C accreditation for cement analysis . are within the prescribed limits for iron, so acceptable (according to ASTM-C requirement).

Author: Tesida Dibar
Country: Equatorial Guinea
Language: English (Spanish)
Genre: Science
Published (Last): 11 September 2004
Pages: 458
PDF File Size: 19.78 Mb
ePub File Size: 15.35 Mb
ISBN: 842-3-96613-300-6
Downloads: 16631
Price: Free* [*Free Regsitration Required]
Uploader: Nik

Specific chemical test methods are provided for ease of reference for those desiring to use them.

Sodium and Potassium Oxides. Reporting of analyses shall be of the following order: It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Any change in test method procedures from those procedures listed in Sections 7—3 0 requires method qualification in accordance with 5.

Link to Active This link will always route to the current Active version of the standard. The alternative test methods generally provide individual determination of specific analytes and may be used alone or as alternates and determinations within the basic scheme at the option of the analyst and as indicated in the individual method.

The same test methods to be used for analysis of cement being tested shall be used for analysis of the CRM cement. No other units of measurement are included in this standard. If the two results do not agree within the permissible variation given in Table 1, the determination shall be repeated until two or three results agree within the permissible variation. Any test methods of demonstrated acceptable precision and bias may be used for analysis of hydraulic cements, including analyses for referee and certification purposes, as explained in Section 3.

ASTM C – 09 Standard Test Methods for Chemical Analysis of Hydraulic Cement

NOTE 1—A blank determination is a procedure which follows all steps of analysis but in the absence of a sample. It is the responsibility of the user of this standard to establish appropriate asm and health practices and determine the applicability of regulatory limitations prior to use. The reference test methods are long accepted classical chemical test methods which provide a reasonably well-integrated basic scheme of analysis for hydraulic cements.

  HOW TO BECOME A DEADLY CHESS TACTICIAN PDF

If the reference cement, as supplied, has no documented guarantee of homogeneity, establish its homogeneity by analyzing at least six randomly selected samples.

When two astk three results do agree within the permissible variation, their average shall be accepted as the correct value. No further reproductions authorized.

ASTM C114 – 15 – Chemical Analysis of Hydraulic Cement

Historical Version s – view previous versions of standard Translated Version s: Description of Referee Analyses. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Any test methods of demonstrated acceptable precision and bias may be used for analysis of hydraulic cements, including analyses for referee and certification purposes, as explained in Section 3.

No other zstm of measurement are included in this standard. When reporting the results of referee analyses, specify which test methods were used. Alternative test methods and procedures include determination of sstm oxide, calcium dioxide, magnesium oxide, loss on ignition, titanium dioxide, phosphorus pentoxide, manganic asrm, and free calcium oxide.

Repeat the determinations until a set of duplicate results agree within the permissible variations. The reference cement is acceptable if its assigned value agrees with the average referee value within the limits given in column 3 of Table 1. The final results, when corrected for blank values, should, in either case, be so designated.

Weigh and prepare two separate specimens of each standard. A reference test method must be used where an alternative test method is not provided.

C114 approved in Performance Requirements for F114 Test Methods. F Demonstrate performance by analysis, in duplicate, of at least one Portland cement. Assign the CO2 content of Standard A as the average of the two values determined, provided they agree within the required limit of Column 2.

The reference test methods are long accepted classical chemical test methods which provide a reasonably well-integrated basic scheme of analysis for hydraulic cements. Active view current version of standard. Performance Requirements for Rapid Test Methods.

  LETTERS FROM HELL RAMON SAMPEDRO PDF

ASTM C – 00 Standard Test Methods for Chemical Analysis of Hydraulic Cement

Zstm view current version of standard. The reference test methods are long accepted wet chemical test methods which provide a adtm well-integrated basic scheme of analysis for hydraulic cements. For the purpose of comparing analyses and calculating the average of acceptable results, the percentages shall be calculated to the nearest 0. Current edition approved April 15, Requirements for Qualification Testing.

Standard reagents for the test method shall be used within the limits of the specification. The standardization used for qualification and for analysis of each constituent shall be determined by valid curve-fitting procedures.

Link to Active This link will always route to the current Active version of the standard. The analyst is considered qualified when the difference between the duplicate results does not vary by more than the value listed in Column 2 of Table 1 and the average of the two samples agrees with the certificate value of the CRM within the limits listed in Column 3 of Table 1 after correction for minor components when needed.

A superscript epsilon indicates an editorial change since the last revision or reapproval. Longer, more complex procedures, in some instances, have been retained as alternative test methods to permit comparison of results by different procedures or for use when unusual materials are being examined, where unusual interferences may be suspected, or when unusual preparation for analysis is required. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

No other units of measurement are included in this standard. Last previous edition approved in as C — When Rapid Methods are used, qualification testing of both the analyst and the test method are c11 as described in 5.